Biomechanical study of the bone tissue with dental implants

Autoři

MARCIÁN P. BORÁK L. FLORIÁN Z. BARTÁKOVÁ Sonia KONEČNÝ O. NAVRÁTIL P.

Rok publikování 2012
Druh Článek v odborném periodiku
Časopis / Zdroj Applied and Computational Mechanics
Fakulta / Pracoviště MU

Lékařská fakulta

Citace
Obor ORL, oftalmologie, stomatologie
Klíčová slova dental implant; trabecular bone;finite elements method;stress and strain analysis;modeling level
Popis The article deals with the stress-strain analysis of human mandible in the physiological state and after the dental implant application. The evaluation is focused on assessing of the cancellous bone tissue modeling-level. Three cancellous bone model-types are assessed: Non-trabecular model with homogenous isotropic material, nontrabecular model with inhomogeneous material obtained from computer tomography data using CT Data Analysis software, and trabecular model built from mandible section image. Computational modeling was chosen as the most suitable solution method and the solution on two-dimensional level was carried out. The results show that strain is more preferable value than stress in case of evaluation of mechanical response in cancellous bone. The non-trabecular model with CT-obtained material model is not acceptable for stress-strain analysis of the cancellous bone for singularities occurring on interfaces of regions with different values of modulus of elasticity
Související projekty:

Používáte starou verzi internetového prohlížeče. Doporučujeme aktualizovat Váš prohlížeč na nejnovější verzi.

Další info