Bilinear elastic property of the periodontal ligament for simulation using a finite element mandible model

Autoři

BORÁK Libor FLORIÁN Zdeněk BARTÁKOVÁ Sonia PRACHÁR Patrik MURAKAMI Natsuko ONA Masahiro IGARASHI Yoshimasa WAKABAYASHI Noriyuki

Rok publikování 2011
Druh Článek v odborném periodiku
Časopis / Zdroj DENTAL MATERIALS JOURNAL
Fakulta / Pracoviště MU

Lékařská fakulta

Citace
Doi http://dx.doi.org/10.4012/dmj.2010-170
Obor ORL, oftalmologie, stomatologie
Klíčová slova final element;periodontal ligaments
Popis In the paper, a newly-created model of periodontium is presented. Data presented in several earlier experimental papers were used for the creation of the model. The bilinear isotropic model of perio-dontium material was applied in simulation model of a single tooth in a whole lower jaw, and its particular segment, respectively. Verification of the model was done by a PC-based system Ansys using finite element method. In the model, the following material characteristics for periodontium were used: Young modulus of elasticity E1 =- 0.05 MPa, E2 = 2.5MPa. Analysis of results of simulation run showed distribution maximum main stress in bony tissue of a lower jaw, pattern of which was related to forces applied in coronoapical and buccolingual directions. Using a newly-created model, a good agreement of simulation results with experimental data was reached. Future development of the model will include periodontal fibres.
Související projekty:

Používáte starou verzi internetového prohlížeče. Doporučujeme aktualizovat Váš prohlížeč na nejnovější verzi.

Další info