Electro-Optical Recording System for Myocardial Ischemia Studies in Animal Experiments

Authors

PROVAZNÍK Ivo NOVÁKOVÁ Marie VESELÝ Zdeněk BLAHA Milan CHMELAŘ Milan

Year of publication 2003
Type Article in Proceedings
Conference Computers in Cardiology
MU Faculty or unit

Faculty of Medicine

Citation
Field Physiology
Keywords electro-optical recording; monophasic action potentials; myocardial ischemia
Description Myocardial ischemia is the most common cause of death in the developed countries. The most severe manifestation is sudden death due to electrical instability, terminating in ventricular fibrillation or heart arrest. This study is based on experiments in which electrograms and monophasic action potentials are recorded from isolated guinea pig hearts perfused according to Langendorff during various phases of acute ischemia and reperfusion. The data are then processed by a wavelet transform in order to obtain complex-valued time-frequency patterns.