Voriconazole plasma levels monitoring in allogeneic haematopoietic stem cell transplant recipients

Authors

WINTEROVÁ Jana RÁČIL Zdeněk MALÁŠKOVÁ L. KOCMANOVÁ I. WEINBERGEROVÁ B. MAYER Jiří

Year of publication 2009
Type Conference abstract
MU Faculty or unit

Faculty of Medicine

Citation
Description Voriconazole plasma levels measurement enables to optimize dosing and improves the effi cacy of antifungal treatment. Methods: Retrospective analysis of documentation and laboratory results of patients after allogeneic transplantation treated with voriconazole from August 2005 to November 2008 was performed. Steady-state plasma Voriconazole levels were obtained using a high-performance liquid chromatography assay.