Kvantitativní vyhodnocení defektu barvocitu - Lanthonyho test a jeho modifikovaná interpretace

Title in English Quantitative Color Vision Defect Evaluation - Lanthony Test and its Modified Interpretation
Authors

VESELÝ Petr URBÁNEK D. SYNEK Svatopluk HANÁK L.

Year of publication 2016
Type Article in Periodical
Magazine / Source Česká a Slovenská oftalmologie
MU Faculty or unit

Faculty of Medicine

Citation
Field ORL, ophthalmology, stomatology
Keywords Lanthony test; color vision defect; index of selectivity; index of confusion; total error score
Description Our aim was to develop quick and exact instrument for examination of color vision defects (CVD). We used Lanthony saturated and desaturated test. Data were evaluated according the Vingrys and King-Smith study. We had together 123 eyes of 86 patients. From all subjects we received these average values: AA 44.32 (min -87.13, max 80.64), TES 13.36 (min 8.84, max 30.30), SI 1.97 (min 1.22, max 5.69) and Cl 1.66 (min 1.0, max 3.94). At the base of counting algorithm and average values form saturated and desaturated test we revealed 25 (29 %) patients with CVD. Twelve patients (14 %) classified as CVD+ had dichromacy and all had inborn CVD. Eight patients (9 %) from this group had deutranopia and four patient (5 %) protanopia. Anomaly trichromacy we revealed in thirteen patients (15 %). Eight (9 %) of these patients had inborn CVD. Six (7 %) of these patients had protanomalia, one (1 %) had deuteranomalia and one tritanomalia. We established and specified TES, Cl and SI critical values, which was used to dividing patients into specific groups.

You are running an old browser version. We recommend updating your browser to its latest version.