Treatment of early localised infection of the Omniflow® II prosthesis with negative pressure wound therapy

Authors

KREJČÍ Miroslav STAFFA Robert GLADIŠ P.

Year of publication 2016
Type Article in Periodical
Magazine / Source Wound Practice and Research
MU Faculty or unit

Faculty of Medicine

Citation
Field Surgery incl. transplantology
Keywords Omniflow® II prosthesis; infection; wound therapy
Description A biosynthetic vascular prosthesis is a special type of vascular graft. Implantation of this type of prosthesis can be considered for patients with limb ischaemia, diabetes mellitus, insufficient saphenous vein, and trophic ulcers. We present a rare case of successful healing of an early Szilagyi grade III vascular prosthetic infection in the groin using a topical negative pressure device and moist wound healing materials.