Selhání revizní náhrady kyčle s Burch- Schneiderovým prstencem

Title in English The failure of the Burch- Schneider ring in revision hip surgery
Authors

ROZKYDAL Zbyněk SKLENSKÝ Martin

Year of publication 2005
Type Article in Proceedings
Conference Abstrakta - XIII. Frejkovy dny
MU Faculty or unit

Faculty of Medicine

Citation
Field Traumatology and orthopaedic surgery
Keywords Revision hip surgery
Description Th authors have used in revision hip surgery with defects Paprosky 3A a 3B Burch- Schneider ring in 52 patients in the years 1980-2000. The mean age was 66 years. The mean follow- up was 10,2 years. They found 10 complications - 5 aseptic and 5 septic loosening of the ring, which was removed later on. They emphasize to create a stable composit: pelvic bone. bone grafts- BS ring- bone cement- polyethylene cup. They use small trabecural bone grafts 10x10 mm in size and a method of compression grafting.